Solar Calculator Canada

Solar Power Calculator for Niagara Falls, Ontario, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Niagara Falls
  • GPS Coordinates: 43.06012, -79.10671
  • Elevation: 186 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Niagara Falls: 34o
  • Average yearly irradiance: 1530.99 kWh/m2
  • Average yearly power output: 128073 kWh
Sun Path Niagara Falls

Average yearly irradiance delivered by the Sun in Niagara Falls is 1530.99/kWh/m2 at the optimal panel slope of 34o. After taking all losses into account, you can expect about 128073 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 34o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2 61.89
February 2.6 72.71
March 4.17 129.3
April 5.13 153.98
May 5.9 182.98
June 5.96 178.68
July 6.13 189.88
August 5.78 179.24
September 4.82 144.61
October 3.33 103.33
November 2.7 80.99
December 1.72 53.41
Total yearly 1530.99

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 181 5611.06
February 235.9 6605.18
March 369.87 11465.8
April 438.73 13162
May 486.88 15093.3
June 480.03 14401
July 487.68 15118.1
August 462.34 14332.6
September 392.42 11772.5
October 281.04 8712.3
November 235.89 7076.71
December 152.34 4722.52
Total yearly 128073

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Niagara Falls solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 144.2 4470.14
February 202.53 5670.84
March 339.1 10512.2
April 431.85 12955.5
May 506.36 15697.2
June 510.31 15309.4
July 513.07 15905.2
August 465.19 14420.9
September 368.23 11046.8
October 246.32 7635.87
November 188.37 5651.02
December 117.63 3646.38
Total yearly 122922

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 155.62 4824.23
February 213.32 5973.07
March 350.16 10855.1
April 436.93 13108
May 504.74 15647.1
June 505.67 15170.2
July 509.62 15798.1
August 467.88 14504.3
September 377.75 11332.4
October 257.79 7991.51
November 203.11 6093.23
December 128.25 3975.76
Total yearly 125273

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 165.86 5141.68
February 222.73 6236.55
March 359.14 11133.5
April 439.7 13190.9
May 500.5 15515.6
June 498.63 14959
July 503.95 15622.4
August 468.19 14513.9
September 385.04 11551.2
October 267.65 8297.02
November 216.33 6489.84
December 137.88 4274.23
Total yearly 126926

Niagara Falls Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 174.89 5421.63
February 230.73 6460.32
March 366.01 11346.4
April 440.08 13202.3
May 493.74 15305.9
June 488.99 14669.5
July 495.78 15369.2
August 465.9 14443
September 390.08 11702.3
October 275.84 8551.18
November 227.98 6839.48
December 146.47 4540.51
Total yearly 127852

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.88% angle of incidence loss and -4.29% temperature and irradiance loss. This totals to about -16.35%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

Clark's HarbourGoderichShelburneCobourgNewmarketBridgewaterLunenburgCollingwoodDigbyAnnapolis RoyalMidlandGravenhurstPerthMiddletonBracebridgeKentvilleStewiackeSt. StephenHuntsvilleParry SoundTruroArnpriorRenfrewHamptonNew GlasgowMurdochville